Dry Block Heater 2

IKA - Dry Block Heater 2

Digital block heater for two aluminum blocks provides precise temperature control in small vessels. Included PT-1000 temperature sensor allows temperature control directly in the sample vessel. It is used with PCR tubes, PCR strips, Greiner tubes, microplates and cuvettes. The block heater is ideal for melting and boiling point determination, enzyme reactions, incubation and activation of cultures, immunoassays, DNA denaturation, culture media tests, coagulation tests, blood-urea-nitrogen determinations and in situ hybridizations.

Stepless adjustable temperature up to 120 °C
Timer: Countdown, adjustable from 1 min to 99h 59min
Counter: Display of heating time
Highly versatile with a large number of blocks
Error code display
Fixed safety circuit
Acoustic signal at end of test

Scope of delivery

Dry Block Heater 2

Block remove tool

PT 1000.60 Temperature sensor, stainless steel

Label/Normering

Downloads

https://www.ika.com/ika/datasheet/download?iProduct=4025200&iLang=1&iCountry=840&filename=DataSheet_Dry_Block_Heater_2.pdf https://www.ika.com/ika/pdf/flyer-catalog/20240613_Selection Guide Dry Block Heater_IWS_EN_websingle.pdf https://www.ika.com/ika/pdf/flyer-catalog/Heating Block_A4_21_07_refresh.pdf https://www.ika.com/ika/pdf/flyer-catalog/20220614_lifescience_brochure_210x280_IWS_EN_screen.pdf

Technische specificaties

Number of blocks: 2
Heat output: 250 W
Heating temperature range: room temp. +5° - 120 °C
Temperature display: yes
Adjustment and display resolution: 1 K
Connection for ext. temperature sensor: CT (DIN12878)
PT 1000 deviation;DIN EN 60751 Kl. A: ≤ ± (0.15 +0.002xITI) K
Temperature stability within the blocks at 37°C *: ±0.2 °C
Temperature stability within the blocks at 60°C *: ±0.4 °C
Temperature Homogenity @ 37°C *: 0.2 K
Temperature Homogenity @ 60°C *: 0.4 K
Heatingrate / Heat up time with external sensor *: 4.5 K/min
Set-up plate material: Aluminium alloy
Set-up plate dimensions: 96 x 152 mm
Fixed safety circuit: 150 °C
Timer: yes
Time setting range: 1 - 5999 min
* Measured in IKA DBH Testingblock: Refer Manual for more details
Dimensions (W x H x D): 151 x 73 x 304 mm
Weight: 1.3 kg
Permissible ambient temperature: 5 - 40 °C
Permissible relative humidity: 80 %
Protection class according to DIN EN 60529: IP 21
Voltage: 115 V
Frequency: 50/60 Hz
Power input: 250 W

Order nummers