Materiaaltesten Fundering Calibration Equipment for Geotechnical Laboratory
Any laboratory needs to verify periodically the calibrations of their electronic measuring systems, in order to produce reliable and accurate results. Equipment for calibrating force, displacement, volume change and pressure measuring devices.
Force measurement
For calibration of force measuring devices we propose the following load cells fitted with digital readout unit, supplied complete with ACCREDIA calibration certificate according to EN ISO 376.
Pressure measurement
Pressure calibrations are performed with a digital pressure gauge, supplied complete with ACCREDIA calibration certificate.
Volume change
Displacment Measurement
Calibration of displacement measuring devices can be performed with either the analogue or digital micrometer 25 and 50 mm travel respectively, 0.001 mm resolution. They are both available, optionally, with a traceable calibration certificate 25 mm and ACCREDIA certificate 50 mm
Local strain measurement
Force measurement
Load cell
Digital readout unit
Pressure measurement
- Linearity and hysteresis: <=0.05%
- Internal resolution: 65000 div.
- Zero and peak function
- Auto power off function.
- Supplied with four 1.5 V AA size alkaline batteries.
Displacment Measurement
Code | 30-WF0652 | 30-WF0653 | 30-WF0653/K |
Type | Analogue/mechanical | Digital | Digital |
Maximum travel [mm] | 25 | 50 | 50 |
Resolution [mm] | 0.001 | 0.001 | 0.001 |
Dimesions (wxdxh) [mm] | 260x60x100 | 300x60x107 | 300x60x107 |
Weight [ kg] | 0.6 | 1.5 | 1.6 |
30-WF0372/SIT: 5kN load cell complete with ACCREDIA calibration certificate and stainless steel loading seat. Certificate issue and calibratin require the load cell to be ordered with the digital load gauge 30-WF0373/SIT: 50kN load cell complete with ACCREDIA calibration and stainless steel loading seat. Certificate issue and calibration require the load cell to be ordered with the digital load gauge
: 30-WF0652: Calibration device for linear transducers up to 25mm travel. It consists of a steel frame with micrometer gauge head 25mm travel x 0,001mm res. 30-WF0652/C: Calibration device for linear transducers up to 25mm travel. It consists of a steel frame with micrometer gauge head 25mm travel x 0,001mm res. Complete with traceable calibration certificate. 30-WF0653: Calibration device for displacement transducers up to 50mm travel. It consists of a steel frame with digital micrometer 50mm travel x 0,001mm res. 30-WF0653/C: Calibration device for linear transducers up to 50mm travel. It consists of a steel frame with digital micrometer head 50mm travel x 0,001mm res.Complete with ACCREDIA calibration certificate. 30-WF0653/K:
Calibration Device for Mini-On sample transducers for local strain measurement in triaxial testing and also standard linear displacement transducers up to 50 mm travel.
: 30-WF6305/SIT: 50bar digital pressure gauge complete with ACCREDIA calibration certificate for pressure transducers calibration purposed 30-WF6601: Digital load gauge for load cells
Een prangend labovraagstuk?