Materiaaltesten Fundering Programmable Accelerated Curing Tanks
Introduction
This test method covers procedures for curing concrete specimens under conditions intended to accelerate the development of strength. Three versions available:
55-C0194/D model which cover the ASTM C684, C1768 (Procedure A, warm water method) and BS 1881:112 for 35-55°C hot water method.
55-C0194/DV similar to the above, but covering steam method.
55-C0194/E model, covering both hot water and steam method.
Description
This special curing tanks have been designed for hot water curing or steam curing in accelerated strength concrete. The interior is made from stainless steel. The electronic programmer can control up to four test cycles with different thermal gradients and curing time to a defined temperature value for a complete automatic curing cycle. The control panel include a 28 column thermal printer.
ASTM C684‰BS 1881:112‰ASTM C1768
C0194/D C0194/DZ | C0194/DV C0194/DVZ | C0194/E C0194/EZ | |
Max water temperature, °C | 90 | - | 90 |
Max steam temperature, °C | - | 100 | 100 |
Temperature sensor | PT 100 | ||
Heating system | Three 1500W electric resistance heaters submerged in water | ||
Submersible circulation pump | - | - | yes |
Cooling system | - | With mains water controlled by solenoid valve* | |
Temperature control | By closed loop PID control system | ||
Temperature curing cycle | Programmable: -Rising time up to the selected value -Maximum temperatur holding time | Programmable: -Rising time up to the selected value -Maximum temperatur holding time -Cooling time down to ambient temperature | |
Power rating, W | 4500 | ||
Printer | 24 column, included | ||
Overall dimensions, mm (w x d x h) | 970 x 1000 x 920 | ||
Internal dimension, mm (w x d x h) | 640 x 900 x 560** |
* Note: cold water is supplied to the bottom of the tank in order it does not hit the specimens
** 400mm is the max height between specimen supporting grid and water level
: 55-C0194/DVZ: Programmable accelerated concrete curing tank, steam method, complete with printer. 220V/60Hz/3ph 55-C0194/DZ: Programmable accelerated concrete curing tank for hot curing method to ASTM C684 and BS 1881:112, complete with printer. 220V, 60Hz, 3ph. 55-C0194/E: Programmable accelerated concrete curing tank, warm/hot water method,to ASTM C684 and BS 1881:112and steam method. Complete with printer. 380V/50Hz/3F 55-C0194/EZ: Programmable accelerated concrete curing tank, warm/hot water method,to ASTM C684 and BS 1881:112and steam method. Complete with printer. 220V/60Hz/3F
Een prangend labovraagstuk?
De oplossing is slechts een
klik van je verwijderd!
info@hilab.be
BE 0838.823.138
Openingsuren:
Ma - Vr: 08u - 17u
Za: enkel op afspraak